RJ12 series channel type pedestrian, line package radiation monitoring equipment

We are a factory producing high-quality pedestrian radiation monitoring equipment. Our RJ12 series channel type equipment comes in a line package, perfect for efficient radiation monitoring. Contact us today!

Request a Quote
  • RJ12 series channel type pedestrian, line package radiation monitoring equipment
  • RJ12 series channel type pedestrian, line package radiation monitoring equipment

PRODUCTS DETAILS

technical feature

project name Parameter information
Types of detectors Plate plastic scintillator + low noise photomultiplier tube
Detector volume 5,10,15 optional with dual probe (door default dual probe)
Maximum pass rate 106cps
energy range 25keV~3MeV
sensitivity m5000cps / (Sv / h) (10 L, relative137Cs)
Detection lower limit Ability to detect radiation above the background of 5nSv / h
Optional one, the neutron tube
  • Probe type: long life3He neutron detector (1 atmospheric or pressure optional)
  • Energy range: 0.025eV (hot neutron) ~14MeV
  • Count of life: 1017A count
  • Effective detection area size: 50mm 600mm, 25mm 600mm, 57mm 1054mm is optional;
  • Sensitivity: 75 cps / Sv / h (relative to the other)m252Cf)
  • Underlying count: <5cps
Optional dinnuclide recognition
  • Detector type: France SAN Gobain bulk sodium iodide detector + low potassium quartz photomultiplier tube
  • Detector volume: 1 l, 2 l optional, equipped with dual probes
  • Maximum pass rate: 106cps
  • Energy range: 25keV~3MeV
  • Sensitivity: 20,000 c p s / (Sv / h) (2 L, relativem137Cs)

 Main technical indicators of the detectors

Main technical indicators of the system

1. Static detection efficiency (A-B) A. Static detection efficiency of the pedestrian monitoring system
radioactive source The main energykeV

Static detection efficiency

Dose rate at 1.5m / (nSv.h-1/MBq
s-1/MBq s-1/(nSv.h-1)
241Am 60 ≥220 ≥94 2.3
57Co 122,136 ≥840 ≥90 9.3
137Cs 662 ≥960 ≥23 42
60Co 1173,1332 ≥1800 ≥11 160
133Ba 3,181,302,356 ≥1680 ≥73 23
pour: 1. The 252Cf neutron standard test source with a strong neutron source of 12000 / s (1 ± 20%) is placed at the location of the detector reference point 2. The neutron count rate shall meet the requirement of the count rate of> 100 (1 ± 20%) / s Static detection efficiency of the B-row package monitoring system
radioactive source The main energykeV

Static detection efficiency

Dose rate at 1.5m / (nSv.h-1/MBq
s-1/MBq s-1/(nSv.h-1)
241Am 59.5 ≥480 ≥92 5.2
57Co 122,136 ≥2400 ≥114 21
137Cs 662 ≥2640 ≥28 95
60Co 1173,1332 ≥5760 ≥16 360
133Ba 3,181,302,356 ≥4560 ≥88 52
2. Detection sensitivity Pedestrian monitoring system and line package monitoring system Pedestrian: Detection probability f 90% speed v=1.2m/s Line package: probe probability f 90% speed v=1m / s
radioactive source Activity or quality
137Cs 0.08MBq
60Co 0.02MBq
241Am 2.27MBq
3. Anti-interference performance of the neutron detector When a 60Co source generates a dose rate at the geometric center of the neutron detector surface of the monitoring system, greater than 120 Sv / h, the monitoring system should not trigger a neutron alarm 4. False alarm rate: 0.01% (, neutron) Probability of a detection system alarm caused by non-radioactive substances or non-SNM 5. overload characteristics When the detector surface dose rate is> 120 Sv / h, the monitoring system shall maintain the alarm state and return to the background state, and the alarm release time is less than 60s. 6. Sensitivity consistency Within the range of the detection area Pedestrian ± 25% Line Pack ± 25%① The BIN (Background Identification of Normal) background ignores the technology ② MCA multispectrum analyzer, characteristic SIGMA statistical algorithm ③ NORM function (40K) Quick distinguish between common artificial and natural nuclides (e. g40K、232Th) ④ Nuclide recognition function (with sodium iodide probe / optional) ⑤ Combining the sodium iodide detector and the MCA multichannel energy spectrometer analyzer can accurately distinguish between medical nuclides, industrial nuclides, and natural radionuclides
Natural nuclide 40K、226Ra、232Th
Industrial nuclide 241Am、137Cs、60Co、57Co、22Na、133Ba、54Mn、88Y
Medical nuclides 131I、201Tl、203Hg、18F、99mTc、99Mo、192Ir
Special nuclear materials 57Co、152Eu、238U
⑥ High-speed sampling (fastest: 200ms)

Misalarm rate

In a stable environment: Use the space sensor, 10000 times, false alarm rate 1 Without using the occupying sensor, the false alarm rate and misidentification rate are used once within 12h γ Radiation Response Occup 50 times, alarm 49 times Outrange Over 100 v S / h, a high radiation alarm is emitted and removed within 1min after the source leaves Radiation-induced neutron alarm No neutron alarm is triggered when the dose rate of γ-ray reaches 100 Sv / h Background influence When the background change is large enough to cause a large change in the alarm probability, the monitoring system shall issue a warning prompt

Nuclide recognition

Natural nuclide 40K、226Ra、232Th
Industrial nuclide 241Am、137Cs、60Co、57Co、22Na、133Ba、54Mn、88Y
Medical nuclides 131I、201Tl、203Hg、18F、99mTc、99Mo、192Ir
Special nuclear materials 57Co、152Eu、238U
Note: Nuclide identification and neutron detection are optional, not in the standard system

Main technical indicators for nuclide identification (optional)

System model

Hot Products

RJ34 Handheld Nuclide Recognition Instrument

RJ34 Handheld Nuclide Recognition Instrument

RJ33 multi-function radioactive detector

RJ33 multi-function radioactive detector

RJ31-1305 personal dose (rate) meter

RJ31-1305 personal dose (rate) meter

RJ21 series Regional Radiation Monitoring System

RJ21 series Regional Radiation Monitoring System

RAIS-1000/2 Series Portable Air Sampler

RAIS-1000/2 Series Portable Air Sampler

ECTW-1 Water Electrolyzer for Tritium Enrichment

ECTW-1 Water Electrolyzer for Tritium Enrichment

RJ32-3602 PIntegrated X pulse radiation survey instrument

RJ32-3602 PIntegrated X pulse radiation survey instrument

RJ11 Series Channel-Type Vehicle Radiation Monitoring Equipment

RJ11 Series Channel-Type Vehicle Radiation Monitoring Equipment

RJ39 Surface contamination detector

RJ39 Surface contamination detector

 RJ14 upright-type radiation detector

RJ14 upright-type radiation detector