RJ12 series channel type pedestrian, line package radiation monitoring equipment
RJ12 series channel type pedestrian, line package radiation monitoring equipment
We are a factory producing high-quality pedestrian radiation monitoring equipment. Our RJ12 series channel type equipment comes in a line package, perfect for efficient radiation monitoring. Contact us today!
5,10,15 optional with dual probe (door default dual probe)
Maximum pass rate
106cps
energy range
25keV~3MeV
sensitivity
m5000cps / (Sv / h) (10 L, relative137Cs)
Detection lower limit
Ability to detect radiation above the background of 5nSv / h
Optional one, the neutron tube
Probe type: long life3He neutron detector (1 atmospheric or pressure optional)
Energy range: 0.025eV (hot neutron) ~14MeV
Count of life: 1017A count
Effective detection area size: 50mm 600mm, 25mm 600mm, 57mm 1054mm is optional;
Sensitivity: 75 cps / Sv / h (relative to the other)m252Cf)
Underlying count: <5cps
Optional dinnuclide recognition
Detector type: France SAN Gobain bulk sodium iodide detector + low potassium quartz photomultiplier tube
Detector volume: 1 l, 2 l optional, equipped with dual probes
Maximum pass rate: 106cps
Energy range: 25keV~3MeV
Sensitivity: 20,000 c p s / (Sv / h) (2 L, relativem137Cs)
Main technical indicators of the detectors
Main technical indicators of the system
1. Static detection efficiency (A-B)A. Static detection efficiency of the pedestrian monitoring system
radioactive source
The main energykeV
Static detection efficiency
Dose rate at 1.5m / (nSv.h-1/MBq
s-1/MBq
s-1/(nSv.h-1)
241Am
60
≥220
≥94
2.3
57Co
122,136
≥840
≥90
9.3
137Cs
662
≥960
≥23
42
60Co
1173,1332
≥1800
≥11
160
133Ba
3,181,302,356
≥1680
≥73
23
pour:1. The 252Cf neutron standard test source with a strong neutron source of 12000 / s (1 ± 20%) is placed at the location of the detector reference point2. The neutron count rate shall meet the requirement of the count rate of> 100 (1 ± 20%) / sStatic detection efficiency of the B-row package monitoring system
radioactive source
The main energykeV
Static detection efficiency
Dose rate at 1.5m / (nSv.h-1/MBq
s-1/MBq
s-1/(nSv.h-1)
241Am
59.5
≥480
≥92
5.2
57Co
122,136
≥2400
≥114
21
137Cs
662
≥2640
≥28
95
60Co
1173,1332
≥5760
≥16
360
133Ba
3,181,302,356
≥4560
≥88
52
2. Detection sensitivityPedestrian monitoring system and line package monitoring systemPedestrian: Detection probability f 90% speed v=1.2m/sLine package: probe probability f 90% speed v=1m / s
radioactive source
Activity or quality
137Cs
0.08MBq
60Co
0.02MBq
241Am
2.27MBq
3. Anti-interference performance of the neutron detectorWhen a 60Co source generates a dose rate at the geometric center of the neutron detector surface of the monitoring system, greater than 120 Sv / h, the monitoring system should not trigger a neutron alarm4. False alarm rate: 0.01% (, neutron)Probability of a detection system alarm caused by non-radioactive substances or non-SNM5. overload characteristicsWhen the detector surface dose rate is> 120 Sv / h, the monitoring system shall maintain the alarm state and return to the background state, and the alarm release time is less than 60s.6. Sensitivity consistencyWithin the range of the detection areaPedestrian ± 25% Line Pack ± 25%① The BIN (Background Identification of Normal) background ignores the technology② MCA multispectrum analyzer, characteristic SIGMA statistical algorithm③ NORM function (40K) Quick distinguish between common artificial and natural nuclides (e. g40K、232Th)④ Nuclide recognition function (with sodium iodide probe / optional)⑤ Combining the sodium iodide detector and the MCA multichannel energy spectrometer analyzer can accurately distinguish between medical nuclides, industrial nuclides, and natural radionuclides
Natural nuclide
40K、226Ra、232Th
Industrial nuclide
241Am、137Cs、60Co、57Co、22Na、133Ba、54Mn、88Y
Medical nuclides
131I、201Tl、203Hg、18F、99mTc、99Mo、192Ir
Special nuclear materials
57Co、152Eu、238U
⑥ High-speed sampling (fastest: 200ms)
Misalarm rate
In a stable environment:Use the space sensor, 10000 times, false alarm rate 1Without using the occupying sensor, the false alarm rate and misidentification rate are used once within 12hγ Radiation ResponseOccup 50 times, alarm 49 timesOutrangeOver 100 v S / h, a high radiation alarm is emitted and removed within 1min after the source leavesRadiation-induced neutron alarmNo neutron alarm is triggered when the dose rate of γ-ray reaches 100 Sv / hBackground influenceWhen the background change is large enough to cause a large change in the alarm probability, the monitoring system shall issue a warning prompt
Nuclide recognition
Natural nuclide
40K、226Ra、232Th
Industrial nuclide
241Am、137Cs、60Co、57Co、22Na、133Ba、54Mn、88Y
Medical nuclides
131I、201Tl、203Hg、18F、99mTc、99Mo、192Ir
Special nuclear materials
57Co、152Eu、238U
Note: Nuclide identification and neutron detection are optional, not in the standard system
Main technical indicators for nuclide identification (optional)